Dead-front, liquid-filled, 34.5kV class to 480Y/277V — 3,609A at the secondary. Sourced to spec from our manufacturer network, with firm pricing inside one business day.
We procure each unit to your exact specification from our manufacturer and supply-partner network — fluid, feed configuration, taps, and accessories confirmed at quote. Tell us your requirement and need-by date.
Adjacent ratings and primary voltages are sourced routinely — compare the other ratings in this range below, or see the full 300–3,000kVA range on the MV Pad-Mounted Transformers page.
Nameplate ratings below. Secondary and primary full-load current are calculated from the kVA and voltage; taps, impedance, dimensions, and weight are confirmed against your spec at quote.
3,000kVA is the top of the published pad-mount range. It is specified where the service calculation lands at or above roughly 2,750kVA — campus master services, data-center utility entrances, and heavy process loads. The secondary delivers 3,609A at 480Y/277V, which typically lands on a standard 4000A main device — confirm the switchgear ampere rating and conductor grouping early.
A 3,000kVA unit supplies 2,400kW of real power to a load at 0.8 power factor, or 2,700kW at 0.9 — the kVA rating is fixed, the kW delivered depends on the load's power factor. Worked example: a 2,150kW load at 0.8 power factor draws 2,688kVA — 90% of this unit’s rating — which is normally the point at which a designer either accepts the margin or steps to the next standard rating.
Secondary full-load current for each rating, so you can size up or down against your calculated load.
| Rating | Primary → Secondary | Secondary amps | |
|---|---|---|---|
| 300kVA | 13.8kV D - 480Y/277V | 361A | View → |
| 750kVA | 13.2kV D - 480Y/277V | 902A | View → |
| 1,000kVA | 13.8kV D - 208Y/120V | 2,776A | View → |
| 1,500kVA | 34.5kV D - 480Y/277V | 1,804A | View → |
| 2,000kVA | 34.5kV D - 480Y/277V | 2,406A | View → |
| 2,550kVA | 34.5kV D - 480Y/277V | 3,067A | View → |
| 3,000kVA | 34.5kV D - 480Y/277V | 3,609A | This unit |
Adjacent ratings and voltage classes are sourced routinely — the full 300–3,000kVA range is on the MV Pad-Mounted Transformers page. MV dry-type (core & coil) units have their own page: MV Dry-Type.
[email protected] · 718-973-0281
Pre-filled with this unit — edit the request freely.
Transformers are our main focus, but we are able to source other electrical equipment to fulfill project needs. Among these include motors, generators, and various types of switchgear. Sourced through the same supply channels, one PO, and the same point of contact ensures consistency and reliability across the board.